Дата обновления:

PRO1 CT7ZYV T855SH

Ключевые характеристики T855SH

Серия
T855SH
Item
Low Voltage Thermostat
750mv Compatible
Yes

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
T855SH
Item
Low Voltage Thermostat
750mv Compatible
Yes
Application
Heat And Cool
Automatic Changeover
Yes
Backlit Screen
Yes
Backlit Screen Color
Blue
Batteries Included
Yes
Battery Backup
Yes
Battery Type
(2) AA Batteries
Changeover Type
Automatic
Color
White
Compatible System Type
Electric Forced Air Furnaces, Gas Forced Air Furnaces, Heat Pump With Aux, Heat Pump Without Aux, Millivolt, PTAC
Control Type
Push Button
Dehumidification Control
Yes
Differential Cool
0.2°F, 2°F
Differential Heat
0.2°F, 2°F
Differential Temp.
+0.2°F to +2°F
Differential Type
Adjustable
Digit Size
Easy Read
Display Color
Blue
Display Type
Digital
Dual Transformer Compatible
Yes
Electrical Connection Type
Hardwired
Fan Settings
Auto On
Filter Change Reminder
Yes
Filter Indicator
Yes
Frequency
50/60 Hz
Housing Color
White
Humidification Control
Yes
Includes
Mounting Hardware
Includes Batteries
Yes
Includes Positive Off
Yes
Key Features
Menu Driven Programming, Private Label Badge System, Room Temperature Calibration Adjustment
Key Pad Lockout
Yes
Low-battery Indicator
Yes
Max. Control Temp.
90°F
Max. Operating Temp.
105°F
Maximum Operating Humidity
90%
Millivolt Compatible
Yes
Min. Control Temp.
44°F
Min. Operating Temp.
32°F
Mounting Direction
Horizontal
Mounting Location
Junction Box, Wall
Number Of Cooling Stages (conventional System)
3
Number Of Cooling Stages (heat Pump System)
3
Number Of Heating Stages (conventional System)
2
Number Of Heating Stages (heat Pump System)
5
Overall Depth
1 1/8"
Overall Height
4 3/8"
Overall Width
4 11/16"
Programmable Fan
Yes
Programming Capability
5-1-1, 7 Days
Sensor Location
Remote
Shape
Rectangle
Smart Connectivity
No Connectivity
Stages Conventional
2 H/3 C Conventional
Stages Cool
2
Stages Heat Pump
5 H/3 C Heat Pump
Stages Heating/cooling
2 H/3 C Conventional, 5 H/3 C Heat Pump
System Settings
Cool-Heat-Off
Temp. Differential
0.2°F to 2°F
Temp. Sensitivity
-1°F to +1°F
Temperature Limiting
Yes
Temperature Scale
Celsius, Fahrenheit
Temperature Settings Per Day
2, 4
Temporary Program Override
Yes
Temporary Temperature Hold
Yes
Terminal Designations
B, C, D, G, H, O, RC, RH, S1, S2, W/E, W2, Y, Y2
Thermostat Type
Low Voltage
Type
Low Voltage
Voltage
24V AC
Wifi Capability
No

PRO1

Термостаты PRO1 обозначены так: T621-2, T755S, T855ISH; датчики и принадлежности имеют префиксы R, Z, E.
Подробнее о бренде