Дата обновления:

REED INSTRUMENTS CD4DAY R6200

Ключевые характеристики R6200

Серия
R6200
Item
Pocket Heat Stress Monitor
Auto Shut-off
Yes (15 Min.)

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
R6200
Item
Pocket Heat Stress Monitor
Auto Shut-off
Yes (15 Min.)
Average
Yes
Backlight
Yes
Backlit Display
Yes
Barometric Pressure Accuracy
-1.5 hPa to +1.5 hPa
Barometric Pressure Measuring Range
300 hPa to 1100 hPa
Barometric Pressure Resolution
1 hPa, 0.1 in. hg, 0.1 mm hg
Batteries Required
Yes
Battery Type
(4) AAA
Black Globe Diameter
2"
Black Globe Temp. Accuracy
-1.1°F to +1.1°F
Black Globe Temp. Range
32°F to 176°F
Data Hold
Yes
Datalogging Capabilities
No
Dew Point/wet Bulb Calculation
Yes
Display
LCD
Heat Index Temp. Accuracy
-1.1°F to +1.1°F
Heat Index Temperature Range
32°F to 122°F
Humidity Accuracy (@ 25°c)
10% Rh to 70% Rh, -3% to +3%, Rest Of Range -5% to +5%
Humidity Measuring Range
5% rh to 95% rh
Humidity Resolution
0.1% RH
Includes Ac Adapter
No
Includes Batteries
Yes
Includes Memory Card
No
Includes Mounting Hardware
No
Internal Memory
Yes, Up to 99 Measurements
Ip/nema Rating
Not Rated
Low Battery Indicator
Yes
Manufacturer Warranty Length
1 yr.
Max. Function
Yes
Min. Function
Yes
No. Of Batteries Required
4
Operating Humidity Range
Greater Than 80%
Operating Temperature Range
32°F to 122°F
Relative Humidity Range
5% rh to 95% rh
Rh Range
5% to 95% Rh
Storage Temp.
-4°F to +122°F
Temp. Accuracy
Air Temperature +/-1.1°F (+/-0.6°C), Black Globe 68°F to 122°F (20-50°C) +/-1.1°F (+/-0.6°C), Other +/-1.8°F (+/-1°C), Wbgt (Indoor) +/-2.7°F (+/-1.5°C), Wbgt (Outdoor) +/-3.6°F (+/-2°C)
Temp. Display Units
°C, °F
Temp. Range
32°F to 122°F, 32°F to 176°F, 59°F to 138.2°F, 59°F to 132.8°F
Temperature Accuracy
+/-1.1°F/+/-0.6°C
Temperature Range
32°F to 122°F
Temperature Resolution
0.1°
User Adjustable Dimensions
6.4" x 2.3" x 1.3"
User Adjustable Low Battery Indicator
Yes
User Adjustable Operating Humidity
Less Than 80%
User Adjustable Power Supply
AAA Batteries, AC Adapter
User Adjustable Storage Humidity
Less Than 90%
User Adjustable Tripod Mountable
Yes
User Adjustable Wbgt Alarm
Yes
User Adjustable Weight
4.8 oz.
Wet Bulb Globe Temp. Accuracy
-2.7°F to +2.7°F, -3.6°F to +3.7°F
Wet Bulb Globe Temperature Range
59°F to 132.8°F, 59°F to 138.2°F
Техническое резюме
Reed Instruments R6200 heat stress meter is ideal for measuring ambient temperature, humidity, pressure, black globe temperature, wet bulb global temperature (WBGT), heat stress index and dew point. It is OSHA recommended to measure the heat stress index telling users how hot it feels by combining humidity with temperature, air movement & radiant heat.

REED INSTRUMENTS

Для снабжения Reed Instruments — большая номенклатура из более чем тысячи позиций. В наименованиях сначала идёт артикул, затем название прибора, поэтому отбор удобно вести по типу измерения.
Подробнее о бренде