REED INSTRUMENTS CD7AAY R2330-NIST
Ключевые характеристики R2330-NIST
- Серия
- R2330-NIST
- Item
- Infrared Thermometer
- Accuracy
- +/-1.8% Of Reading Or +/-1.8° Whichever Is Greater (Basic), +/-1.8% Of Reading Or +/-1.8° Whichever Is Greater (Detailed Above 0°), +/-1.8° +/0.1° (Below 0°)
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- R2330-NIST
- Item
- Infrared Thermometer
- Accuracy
- +/-1.8% Of Reading Or +/-1.8° Whichever Is Greater (Basic), +/-1.8% Of Reading Or +/-1.8° Whichever Is Greater (Detailed Above 0°), +/-1.8° +/0.1° (Below 0°)
- Accuracy °f
- +/-1.8% Of Reading Or +/-3.6° Whichever Is Greater (Above 32°), +/-1.8% Of Reading Or +/-3.6° Whichever Is Greater (Basic), +/-3.6° +/0.1° (Below 32°)
- Auto Power Off
- Yes
- Batteries Included
- Yes
- Battery Run Time
- 10 hrs.
- Battery Size
- 9V
- Battery Voltage
- 9V
- Body Style
- Full Size
- Calibration Certificate Type
- NIST
- Calibration Certification_combined
- Nist R2330-Nist
- Digital Display Screen Type
- LCD With Backlight
- Distance To Spot Ratio
- 50:1
- Emissivity
- 0.1 to 1
- Emissivity Adjustability
- Adjustable
- Features
- Dual Lasers Assist With Target Area Identification And Allow For Precise Temperature Measurements To Meet The Needs Of Industrial, Electrical And Hvac/R Professionals
- Includes Work Light
- No
- Intrinsic Safety
- Not Specified Intrinsically Safe
- Laser Sighting Type
- Dual
- Manufacturer Warranty Length
- 1 yr.
- Max. Emissivity
- 1
- Max. Emissivity Setting
- 1
- Max. Operating Temperature °f
- 122°F
- Max. Temp. Measured
- 2282°F
- Max. Temperature Measured
- Over 1202°F
- Maximum Temperature Measured °c
- 1250°C
- Maximum Temperature Measured °f
- 2282°F
- Min. Emissivity
- 0.1
- Min. Temp. Measured
- -26°
- Minimum Emissivity Setting
- 0.10
- Minimum Operating Temperature °f
- 32°F
- Minimum Temperature Measured °c
- -32°C
- Minimum Temperature Measured °f
- -26°F
- Mounting Style
- Tripod
- Number Of Batteries Required
- 1
- Operating Temp. Range
- 32°F to 122°F
- Resolution °c
- 0.1°C
- Resolution °f
- 0.1°F
- Temp. Measured Range
- -26°F to +2282°F
- Temperature Alerts
- High Temperature, Low Temperature
- Testing Functions
- Average, Difference, Maximum Temperature, Minimum Temperature
- Standards
- CE, CLASS II LASER, ROHS
REED INSTRUMENTS
Для снабжения Reed Instruments — большая номенклатура из более чем тысячи позиций. В наименованиях сначала идёт артикул, затем название прибора, поэтому отбор удобно вести по типу измерения.
Подробнее о бренде