- Серия
- R9905
- Item
- Meter
- Alarm
- Low, High
- Alert Type
- Sound
- Analyzer Type
- Gas Analyzers For Carbon Dioxide
- Auto Power Off
- Yes
- Backlit Display
- Yes
- Batteries Included
- Yes
- Battery Life
- 10 hrs.
- Battery Run Time
- 10 hrs.
- Battery Voltage
- 9V
- Calibration Certificate
- No
- Calibration Certificate Included
- No
- Calibration Certificate Type
- Available Separately
- Carbon Dioxide Accuracy
- 0 ppm to 5000 ppm, +/-(75 ppm +3% rdg.), 5001 ppm to 30000 ppm, +/-(150ppm +5% rdg.)
- Carbon Dioxide Measuring Ranges
- 0 ppm to 30000 ppm
- Carbon Dioxide Resolution
- 1 ppm
- Carbon Dioxide Sampling Rate
- 2 sec.
- Carbon Dioxide Sensor Type
- Non Dispersive Infrared
- Carbon Dioxide Short Term Exposure Limit (stel)
- 15 min.
- Carbon Dioxide Time Weighted Average (twa)
- 8 hrs.
- Carbon Dioxide Warm-up Time
- 20 sec.
- Data Hold
- Yes
- Datalogging Capabilities
- Yes
- Digital Display Screen Type
- LCD With Backlight
- Dimensions
- 11 1/5" x 2 3/5" x 1 1/2"
- Display Type
- LCD
- Gases Detected
- Carbon Dioxide
- Humidity Accuracy
- 10% to 90% rh, -3% to 3% < 10% & > 90% rh, -5% to +5%
- Humidity Measuring Range
- 0% rh to 100% rh
- Humidity Resolution
- 0.1% RH
- Includes
- Carrying Case, USB Cable
- Internal Memory
- Yes, 32000 Datapoints
- Kick Stand
- Yes
- Low-battery Indicator
- Yes
- Manufacturer Warranty Length
- 1 yr.
- Max. Operating Altitude
- 6561 ft.
- Max. Pressure Measured
- Not Applicable
- Max. Relative Humidity Measured
- 100%
- Maximum Carbon Dioxide Measured
- 30000 ppm
- Maximum Carbon Monoxide Measured
- Not Applicable
- Maximum Temperature Measured
- 140°F
- Min./max./average Readings
- Yes
- Minimum Carbon Dioxide Measured
- 0 ppm
- Minimum Dew Point Measured
- Not Applicable
- Minimum Oxygen Measured
- Not Applicable
- Minimum Relative Humidity Measured
- 0%
- Minimum Temperature Measured
- -4°F
- No. Of Records Stored
- 32000
- Operating Humidity
- 0% to 90%
- Operating Temp.
- 32°F to 122°F
- Pc Connectivity
- Usb
- Power Source
- Battery
- Ppm Accuracy
- +/-3% Of Reading, +/-75 ppm (0 ppm to 5, 000 ppm), +/-5% Of Reading, +/-150 ppm (5001 ppm to 30000 ppm)
- Real-time Clock And Date Stamp
- Yes
- Relative Humidity Accuracy
- +/-3% From 10 to 90% Rh, +/-5% From 10 to 90% Rh
- Relative Humidity Range
- 0% to 100%
- Selectable Sampling Rate
- Yes
- Software Os Compatability
- Windows 7, 8, 10, 11
- Storage Humidity Range
- 10% to 75%
- Storage Temp.
- -4°F to +140°F
- Temp. Range
- -4°F to +140°F
- Temp. Resolution
- 0.1°F
- Temperature Accuracy
- -1.5° to +1.5°
- Testing Functions
- Relative Humidity, Temperature