REED INSTRUMENTS CT8VRZ R9905

Ключевые характеристики R9905

Серия
R9905
Item
Meter
Alarm
Low, High

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
R9905
Item
Meter
Alarm
Low, High
Alert Type
Sound
Analyzer Type
Gas Analyzers For Carbon Dioxide
Auto Power Off
Yes
Backlit Display
Yes
Batteries Included
Yes
Battery Life
10 hrs.
Battery Run Time
10 hrs.
Battery Voltage
9V
Calibration Certificate
No
Calibration Certificate Included
No
Calibration Certificate Type
Available Separately
Carbon Dioxide Accuracy
0 ppm to 5000 ppm, +/-(75 ppm +3% rdg.), 5001 ppm to 30000 ppm, +/-(150ppm +5% rdg.)
Carbon Dioxide Measuring Ranges
0 ppm to 30000 ppm
Carbon Dioxide Resolution
1 ppm
Carbon Dioxide Sampling Rate
2 sec.
Carbon Dioxide Sensor Type
Non Dispersive Infrared
Carbon Dioxide Short Term Exposure Limit (stel)
15 min.
Carbon Dioxide Time Weighted Average (twa)
8 hrs.
Carbon Dioxide Warm-up Time
20 sec.
Data Hold
Yes
Datalogging Capabilities
Yes
Digital Display Screen Type
LCD With Backlight
Dimensions
11 1/5" x 2 3/5" x 1 1/2"
Display Type
LCD
Gases Detected
Carbon Dioxide
Humidity Accuracy
10% to 90% rh, -3% to 3% < 10% & > 90% rh, -5% to +5%
Humidity Measuring Range
0% rh to 100% rh
Humidity Resolution
0.1% RH
Includes
Carrying Case, USB Cable
Internal Memory
Yes, 32000 Datapoints
Kick Stand
Yes
Low-battery Indicator
Yes
Manufacturer Warranty Length
1 yr.
Max. Operating Altitude
6561 ft.
Max. Pressure Measured
Not Applicable
Max. Relative Humidity Measured
100%
Maximum Carbon Dioxide Measured
30000 ppm
Maximum Carbon Monoxide Measured
Not Applicable
Maximum Temperature Measured
140°F
Min./max./average Readings
Yes
Minimum Carbon Dioxide Measured
0 ppm
Minimum Dew Point Measured
Not Applicable
Minimum Oxygen Measured
Not Applicable
Minimum Relative Humidity Measured
0%
Minimum Temperature Measured
-4°F
No. Of Records Stored
32000
Operating Humidity
0% to 90%
Operating Temp.
32°F to 122°F
Pc Connectivity
Usb
Power Source
Battery
Ppm Accuracy
+/-3% Of Reading, +/-75 ppm (0 ppm to 5, 000 ppm), +/-5% Of Reading, +/-150 ppm (5001 ppm to 30000 ppm)
Real-time Clock And Date Stamp
Yes
Relative Humidity Accuracy
+/-3% From 10 to 90% Rh, +/-5% From 10 to 90% Rh
Relative Humidity Range
0% to 100%
Selectable Sampling Rate
Yes
Software Os Compatability
Windows 7, 8, 10, 11
Storage Humidity Range
10% to 75%
Storage Temp.
-4°F to +140°F
Temp. Range
-4°F to +140°F
Temp. Resolution
0.1°F
Temperature Accuracy
-1.5° to +1.5°
Testing Functions
Relative Humidity, Temperature

REED INSTRUMENTS

Reed Instruments в эксплуатации работает на объекте: при обходе оборудования, проверке микроклимата, контроле шума и освещения. Результат зависит от поверки прибора и условий замера.