REED INSTRUMENTS CH6RGZ R2450SD

Ключевые характеристики R2450SD

Серия
R2450SD
Item
Thermocouple Thermometer
Accuracy
-327°F to +999.9°F, +/-(0.4% + 1.8°F), 1000°F to 1562°F, +/-(0.4% + 2°F), -199.9°C to +850°C, +/-(0.4% + 1°C) , 32°F to 3092°F, +/-(0.5% + 5°F), 0°C to 1700°C, +/-(0.5% + 3°C) , ±0.4% +1.8°F, 1°C

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
R2450SD
Item
Thermocouple Thermometer
Accuracy
-327°F to +999.9°F, +/-(0.4% + 1.8°F), 1000°F to 1562°F, +/-(0.4% + 2°F), -199.9°C to +850°C, +/-(0.4% + 1°C) , 32°F to 3092°F, +/-(0.5% + 5°F), 0°C to 1700°C, +/-(0.5% + 3°C) , ±0.4% +1.8°F, 1°C
Accuracy Rtd Pt100 Ohm
-327°F to +999.9°F, +/-(0.4% + 1.8°F), 1000°F to 1562°F, +/-(0.4% + 2°F), -199.9°C to +850°C, +/-(0.4% + 1°C)
Accuracy Type E
-148°F to -58.1°F, +/-(0.4% + 1.8°F), -58°F to +999.9°F, +/-(0.4% + 1°F), 1000°F to 1652°F, +/-(0.4% + 2°F), -100°C to -50.1°C, +/-(0.4% + 1°C), -50°C to +900°C, +/-(0.4% + 0.5°C)
Accuracy Type J
-148°F to -58.1°F, ±(0.4% + 1.8°F), -58°F to 999.9°F, ±(0.4% + 1°F), 1000°F to 2102°F, ±(0.4% + 2°F), -100°C to -50.1°C, ±(0.4% + 1°C), -50°C to 999.9°C, ±(0.4% + 0.5°C), 1000°C to 1150°C, ±(0.4% + 1°...Read More-148°F to -58.1°F, ±(0.4% + 1.8°F), -58°F to 999.9°F, ±(0.4% + 1°F), 1000°F to 2102°F, ±(0.4% + 2°F), -100°C to -50.1°C, ±(0.4% + 1°C), -50°C to 999.9°C, ±(0.4% + 0.5°C), 1000°C to 1150°C, ±(0.4% + 1°C)
Accuracy Type K
-148°F to -58.1°F, +/-(0.4% + 1.8°F), -58°F to 999.9°F, +/-(0.4% + 1°F), 1000°F to 2372°F, +/-(0.4% + 2°F), -100°C to -50.1°C, +/-(0.4% + 1°C), -50°C to 999.9°C, +/-(0.4% + 0.5°C), 1000°C to 1300°C, +...Read More-148°F to -58.1°F, +/-(0.4% + 1.8°F), -58°F to 999.9°F, +/-(0.4% + 1°F), 1000°F to 2372°F, +/-(0.4% + 2°F), -100°C to -50.1°C, +/-(0.4% + 1°C), -50°C to 999.9°C, +/-(0.4% + 0.5°C), 1000°C to 1300°C, +/-(0.4% + 1°C)
Accuracy Type R
32°F to 3092°F, +/-(0.5% + 5°F), 0°C to 1700°C, +/-(0.5% + 3°C)
Accuracy Type S
32°F to 2732°F, +/-(0.5% + 5°F), 0°C to 1500°C, +/-(0.5% + 3°C)
Accuracy Type T
-148°F to -58.1°F, ±(0.4% + 1.8°F), -58°F to 752.0°F, ±(0.4% + 1°F), -100°C to -50.1°C, ±(0.4% + 1°C), -50°C to 400.0°C, ±(0.4% + 0.5°C)
Auto Power Off
Yes
Backlit
Yes
Calibration Certificate
No
Calibration Certificate Included
No
Data Hold
Yes
Data Logging
Yes
Data Output
Yes Rs 232
Data Output Type
RS 232
Data Storage
Yes
Differential Measurement (t1-t2)
Yes
Digit Height
20 mm
Digital Display
38 mm H x 53 mm W Display With 3.5 Digit Backlit LCD 20 mm Digit Height
Dimensions
7" x 2.7" x 1.8"
Display Height
38 mm
Display Size
38 mm x 53 mm
Display Type
Quad Display, Lcd
Display Width
53 mm
External Memory
Yes, Expandable Up to 16 GB With SD Card
For Rtd Type
PT 100
For Thermocouple Type
Type E, Type J, Type K, Type R, Type S, Type T
Functions
°F/°C Switchable, 2-Channel Rtd Temperature Measurement, 4-Channel Thermocouple Temperature Measurement, Data Hold, Date/Time Stamp, Low Battery Indication, Maximum And Minimum Indicators, Thermocoupl...Read More°F/°C Switchable, 2-Channel Rtd Temperature Measurement, 4-Channel Thermocouple Temperature Measurement, Data Hold, Date/Time Stamp, Low Battery Indication, Maximum And Minimum Indicators, Thermocouple Input Type
Height
20 mm
Humidity Range
10% to 85%
Included Probes
Mini-Type
Includes
Batteries
Includes Batteries
Yes
Includes Nist-traceable Certificate
No
Includes Wireless Transmission
No
Kick Stand
Yes
Low Battery Indicator
Yes
Manufacturer Warranty Length
1 yr.
Max. Function
Yes
Measurement Range Rtd Pt100 Ohm
-327.9°F to +1562°F
Measurement Range Type E
-148°F to +1652°F
Measurement Range Type J
-148°F to +2102°F
Measurement Range Type K
-148°F To +2372°F
Measurement Range Type R
32°F to +3092°F
Measurement Range Type S
32°F to 2732°F
Measurement Range Type T
-148°F to +752°F
Memory
Min/Max
Min. Function
Yes
No. Of Batteries
6
No. Of Batteries Required
6
Number Of Channels
4
Number Of Digits
3.5
Number Of Inputs
4
Operating Humidity
Less Than 85% Rh
Operating Temp.
32°F to 122°F
Power Source Details
(6) AA Batteries
Real-time Clock And Date Stamp
Yes
Resistance
100 ohms
Resolution
0.1°F, 0.1°C, 1°F, 1°C
Resolution Rtd Pt100 Ohm
0.1°F, 1°F >= 1000°
Resolution Type E
0.1°F, 1°F >= 1000°
Resolution Type J
0.1°F, 1°F >= 1000°
Resolution Type K
0.1°F, 1°F >= 1000°
Resolution Type R
1°F
Resolution Type S
1°F
Resolution Type T
0.1°F
Response Time
1x per sec.
Rtd Resistance
100 ohms
Rtd Temperature Range °c
-199.9°C to +850°C
Rtd Temperature Range °f
-327.9°F to +1562°F
Sampling Rate
1 sec. to 3600 sec.
Sd Card Class Compatibility
Class 4
Selectable Sampling Rate
Yes, 1 sec., 2 sec., 5 sec., 10 sec., 30 sec., 60 sec., 120 sec., 300 sec., 600 sec., 1800 sec., 3600 sec.
Sensor Type
Rtd, Thermocouple
Storage Temp.
14°F to 140°F
Temp. Range
-199.99° to +850°, -327.9° to +1562°
Temperature Meter Type
Multichannel Thermocouple Temperature Meter With Data Output And Min/Max
Temperature Range
-148°F to +3092°F (Thermocouple), -327.9°F to +1562°F (Rtd)
Thermocouple Temperature Range C
-100°C to 1150°C (type j),-100°C to 1300°C (type k),-100°C to 400°C (type t),-100°C to 900°C (type e), 0°C to 1500° (type s), 0°C to 1700°C (type r)
Thermocouple Temperature Range F
-148°F to 1652° (Type E), -148°F to 2102°F (Type J), -148°F to 2372°F (Type K), -148°F to 752°F (Type T), 32°F to 2732°F (Type S), 32°F to 3092°F (Type R)
Tripod Mountable
Yes
Type
4 Channel Thermocouple, 2 Channel RTD
Техническое резюме
REED Instruments R2450SD data logging thermometer is ideal for recording temperatures, up to 3092 degrees F, either manually or automatically at the desired sampling rate from 1 to 3600 seconds. This data logging thermometer comes with a beaded wire probe, a soft carrying case & batteries for use in medical, educational, R&D, pharmaceutical, food service and environmental monitoring applications.

REED INSTRUMENTS

Reed Instruments с точки зрения инженера — измерительная техника для разных величин: манометры, термометры, люксметры, клещи, зонды. Внутри группы приборы различаются диапазоном и точностью, их сверяют по паспорту.
Подробнее о бренде