Дата обновления:

Square D AF6PRX HGL36040

Ключевые характеристики HGL36040

Серия
HGL36040
Item
Circuit Breaker
Ac Voltage Rating
600V AC

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
HGL36040
Item
Circuit Breaker
Ac Voltage Rating
600V AC
Actuator Type
Toggle
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
40A
Awg Gauge
14 AWG to 3/0 AWG
Breaking Capacity
65 kA 240V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 18 kA 600V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 20 kA 500V DC UL 489
Breaking Capacity Code
G
Circuit Breaker Actuator
Toggle
Circuit Breaker Application
HACR Rated
Circuit Breaker Mounting Style
Free Standing
Circuit Breaker Type
Standard
Color
Black
Communication Interface
Modbus, Ethernet
Component Type
Circuit Breaker
Continuous Amps Rating
80%
Control Type
Toggle
Dc Voltage
250V DC
Dc Voltage Rating
250/500V DC
Depth
3.4" , 4.36"
Device Application
Distribution
Electrical Connection
Lugs, Line, Load
Frame Size
150A/HG
Height
6 2/5"
High Amp Trip Setting
850A
Instantaneous Trip
Fixed
Ip Degree Of Protection
IP40
Line Rated Amps
40A
Local Signalling
Switched Off 1 Trip Indicator Green
Low Amp Trip Setting
400A
Magnetic Hold Amps
400A
Magnetic Hold Current
400A
Magnetic Tripping Amps
850A
Magnetic Tripping Current
850A
Max. Air Rating
65 kA At 240V AC
Max. Breaking Capacity
65 kA @ 240V AC
Max. Operating Temp.
104°F
Max. Wire Size
3 AWG
Min. Wire Size
14 AWG
Mounting
Free Standing
Mounting Mode
Unit Mount Lug
Mounting Style
Free Standing
Mounting Support
Lug
Network Frequency
50/60 Hz
No. Of Poles
3
Number Of Poles
3
Number Of Slots
5
Operating Altitude
0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase
3
Phase Connection
ABC
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
0.6"
Quality Labels
ce.png
Quantity Per Set
1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
750V
Rated Operational Voltage
690V
Rated Service Breaking Capacity
65 kA @ 220/240V AC @ 50/60 Hz, 35 kA @ 380/440/415V AC @ 50/60 Hz, 18 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
Returnability
Yes
Suitability For Isolation
Yes, IEC 60947-2
Terminal Connection
Line/Load Lug
Terminal Connection Type
Line, Load Lug
Tightening Torque
44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG
Trip Type
Thermal Magnetic
Trip Unit Technology
Thermal-Magnetic
Utilisation Category
Category A
Width
4.09" , 4.12"
Standards
CE, CSA, IEC, UL LISTED
Warranty
18 Months
Техническое резюме
Square D HGL36040 circuit breaker is designed for use in electrical systems with voltage ratings up to 600VAC. This circuit breaker is used in industrial and commercial settings to protect circuits and equipment from overloads and short circuits. It is ideal for maintaining electrical safety by interrupting current flow when abnormalities occur, preventing damage and fire hazards.
Документация

Square D

Выключатель подбирают по номинальному току, числу полюсов и напряжению, контактор — по току и напряжению катушки. В запросе нужен полный номер с шильдика; если он не читается, приложите фото.
Подробнее о бренде