Square D AF9HDC HGA36110

Ключевые характеристики HGA36110

Серия
HGA36110
Item
Circuit Breaker
Ac Voltage Rating
600V AC

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
HGA36110
Item
Circuit Breaker
Ac Voltage Rating
600V AC
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
110A
Awg Gauge
14 AWG to 3/0 AWG
Breaking Capacity
65 kA 240V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 18 kA 600V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 20 kA 500V DC UL 489
Breaking Capacity Code
G
Circuit Breaker Actuator
Toggle
Circuit Breaker Application
HACR Rated
Circuit Breaker Mounting Style
I-Line
Circuit Breaker Type
Standard
Color
Black
Communication Interface
Modbus, Ethernet
Component Type
Circuit Breaker
Continuous Amps Rating
80%
Control Type
Toggle
Dc Voltage
250V DC
Dc Voltage Rating
250V AC
Depth
3.4" , 4.8"
Device Application
Distribution
Electrical Connection
I-Line Connection, Line, Lugs, Load
For Use With
I Line Panelboards
Frame Size
150A/HG
Height
6 2/5" , 9.73"
High Amp Trip Setting
1700A
Instantaneous Trip
Fixed
Ip Degree Of Protection
IP40
Line Rated Amps
110A
Local Signalling
Switched Off 1 Trip Indicator Green
Low Amp Trip Setting
900A
Magnetic Hold Amps
900A
Magnetic Tripping Amps
1700A
Max. Air Rating
65 kA At 240V AC
Max. Operating Temp.
104°F
Max. Wire Size
3 AWG
Min. Wire Size
14 AWG
Mounting
Plug In Panelboard
Mounting Height
4.5"
Mounting Mode
I Line Bracket
Mounting Support
Bracket
Network Frequency
50/60 Hz
No. Of Poles
3
Number Of Poles
3
Number Of Slots
5
Operating Altitude
0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase
3
Phase Connection
ABC
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
0.6"
Quality Labels
ce.png
Quantity Per Set
1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
750V
Rated Operational Voltage
690V
Rated Service Breaking Capacity
65 kA @ 220/240V AC @ 50/60 Hz, 35 kA @ 380/440/415V AC @ 50/60 Hz, 18 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
Returnability
Yes
Series
HG Series
Suitability For Isolation
Yes, IEC 60947-2
Terminal Connection
Lug
Terminal Connection Type
Lug
Tightening Torque
44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG
Trip Type
Thermal Magnetic
Trip Unit Technology
Thermal-Magnetic
Utilisation Category
Category A
Width
4.09" , 4.48"
Standards
CE, CSA, IEC, UL LISTED
Warranty
18 Months