Square D AG7FVT PJL36120
Ключевые характеристики
- Серия
- PJL36120
- Item
- Circuit Breaker
- Ac Voltage Rating
- 600V AC
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 1200A
- Awg Gauge
- 3/0 AWG to 500 kcmil
- Breaking Capacity
- AIR 100 kA 240V AC 50/60 Hz UL 489, AIR 65 kA 480V AC 50/60 Hz UL 489, AIR 25 kA 600V AC 50/60 Hz UL 489, Icu 65 kA 240V AC 50/60 Hz IEC 60947-2, Icu 50 kA 380/415V AC 50/60 Hz IEC 60947-2
- Breaking Capacity Code
- J
- Circuit Breaker Actuator
- Toggle
- Circuit Breaker Application
- HACR Rated
- Circuit Breaker Mounting Style
- Lug In/Lug Out
- Circuit Breaker Type
- Standard
- Component Type
- Circuit Breaker
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Dc Voltage
- Not Rated
- Dc Voltage Rating
- Not Rated
- Depth
- 8.05" , 8.1"
- Device Application
- Distribution
- Electrical Connection
- Lugs, Line, Load
- For Use With
- Equipment Gear
- Frame
- 1200A/P
- Height
- 12.9" , 16.16"
- High Amp Trip Setting
- 12000A
- Instantaneous Trip
- Adjustable
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 1200A
- Local Signalling
- 1 Trip Indicator Green
- Long Time Pick-up Adjustment Range
- 1"
- Low Amp Trip Setting
- 2400A
- Max. Air Rating
- 25 kA At 600V AC
- Max. Wire Size
- 500 MCM
- Min. Wire Size
- 3/0 AWG
- Mounting
- Lug In, Lug Out
- Mounting Mode
- Unit Mount Lug
- Mounting Support
- Lug
- Network Frequency
- 50/60 Hz
- No. Of Poles
- 3
- Number Of Poles
- 3
- Number Of Slots
- 5
- Operating Altitude
- 0 ft.. to 6561.68 ft. Without Derating, 13123.36 ft. With Derating
- Phase
- 3
- Phase Connection
- ABC
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 1.2"
- Quality Labels
- ce.png
- Quantity Per Set
- 1
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 750V
- Rated Operational Voltage
- 600V
- Rated Service Breaking Capacity
- 35 kA @ 240V AC @ 50/60 Hz, 25 kA @ 380/415V AC @ 50/60 Hz
- Returnability
- Yes
- Series
- PJ Series
- Suitability For Isolation
- Yes, IEC 60947-2
- Terminal Connection
- Box Lug
- Terminal Connection Type
- Box Lug
- Tightening Torque
- 442.5 lbf.in. @ 0.1 sq. in. to 0.4 sq. in. @ 4 x 3/0 AWG to 500 kcmil, 8.9 lbf.in. to 11.5 lbf.in.
- Trip Type
- Electronic
- Trip Unit Name
- ET 1.0I
- Trip Unit Technology
- Electronic, Basic, ET 1I, I
- Utilisation Category
- Category A
- Width
- 8.27" , 8.3"
- Standards
- BS, CCC, CEI, CSA CERTIFIED, FEDERAL SPECIFICATION W-C-375B/GEN, IEC, NEMA, NMX, UL LISTED, UNE, UTE, VDE
- Warranty
- 18 Months
Техническое резюме
PowerPact P Series molded case circuit breaker used to provide overload and short circuit protection in power distribution system, Features the patented Micrologic electronic trip unit for metering and monitoring the current limiting functions, Compact size and small footprint of the P-frame makes it ideal for installation on I-Line panelboards and switchboards, UL listed and IEC / CSA certified, Interrupt capacity - 100 kAIC 240 V AC; 65 kAIC 480 V AC; and 25 kAIC 600 V AC, PowerPact P Series molded case circuit breaker used to provide overload and short circuit protection in power distribution system, Features the patented Micrologic electronic trip unit for metering and monitoring the current limiting functions, Compact size and small footprint of the P-frame makes it ideal for installation on I-Line panelboards and switchboards, UL listed and IEC / CSA certified, Interrupt capacity - 100 kAIC 240 V AC; 65 kAIC 480 V AC; and 25 kAIC 600 V AC