Дата обновления:

Square D CE6GQL BDA260302

Ключевые характеристики BDA260302

Серия
BDA260302
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
BDA260302
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
30A
Awg Gauge
14 AWG to 2/0 AWG
Breaking Capacity
25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489
Breaking Capacity Code
D
Circuit Breaker Application
HACR Rated
Color
Gray
Component Type
Circuit Breaker
Connection Pitch
1.06"
Continuous Amps Rating
80%
Control Type
Toggle
Depth
3 1/2"
Device Application
Distribution
Electrical Connection
I-Line Connection, Line, Lugs, Load
Electrical Durability
10000 Cycles
Frame Type
BDA
Height
5 2/5"
Ik Degree Of Protection
IK07
Ip Degree Of Protection
IP40
Line Rated Amps
30A
Local Signalling
Presence Of Auxiliary Contacts Flag Green
Mechanical Durability
20000 Cycles
Mounting Height
3"
Mounting Mode
I Line
Network Frequency
50/60 Hz
No. Of 9 Mm Pitches
6
No. Of Poles
2
Number Of Poles
2
Number Of Slots
2
Operating Altitude
0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase Connection
AC
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
0.8"
Quality Labels
ce.png
Quantity Per Set
Set of 1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
800V
Rated Operational Voltage
525V
Rated Service Breaking Capacity
25 kA @ 220-240V AC @ 50/60 Hz, 14 kA @ 500-525V AC @ 50/60 Hz, 18 kA @ 380-415V AC @ 50/60 Hz, 18 kA @ 440V AC @ 50/60 Hz
Returnability
Yes
Suitability For Isolation
Yes, IEC 60947-2
Tightening Torque
31.9 lbf.in. to 38.9 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 44.3 lbf.in. to 54.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 2/0 AWG
Trip Unit Technology
Thermal-Magnetic
Utilisation Category
Category A
Voltage
600V
Voltage Type
AC
Width
2.1"
Техническое резюме
Square D BDA260302 circuit breaker designed for protecting sensitive electrical circuits against overload or short-circuit conditions, I-Line plug-in design with mechanical lug terminals on load side for easy installation, wiring, maintenance and quick replacement, Thermal magnetic trip unit delivers both time-delayed & instantaneous current limiting functions, UL-listed, CSA-certified & IEC-approved, Square D BDA260302 circuit breaker designed for protecting sensitive electrical circuits against overload or short-circuit conditions, I-Line plug-in design with mechanical lug terminals on load side for easy installation, wiring, maintenance and quick replacement, Thermal magnetic trip unit delivers both time-delayed & instantaneous current limiting functions, UL-listed, CSA-certified & IEC-approved

Square D

Выключатель подбирают по номинальному току, числу полюсов и напряжению, контактор — по току и напряжению катушки. В запросе нужен полный номер с шильдика; если он не читается, приложите фото.
Подробнее о бренде