Square D CE6GTF BGA34060Y
Ключевые характеристики
- Серия
- BGA34060Y
- Item
- Circuit Breaker
- Ac Voltage Rating
- 525V AC
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 60A
- Awg Gauge
- 14 AWG to 2/0 AWG
- Breaking Capacity
- 65 kA 208Y/120V AC 50/60 Hz UL 489, 65 kA 240V AC 50/60 Hz UL 489, 35 kA 480/277V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 18 kA 600Y/347V AC 50/60 Hz UL 489
- Breaking Capacity Code
- G
- Circuit Breaker Actuator
- Toggle
- Circuit Breaker Application
- HACR Rated
- Circuit Breaker Mounting Style
- I-Line
- Circuit Breaker Type
- Standard
- Color
- Gray
- Component Type
- Circuit Breaker
- Connection Pitch
- 1.06"
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Dc Voltage Rating
- Not Rated
- Depth
- 3.5"
- Device Application
- Distribution
- Electrical Connection
- I-Line Connection, Line, Lugs, Load
- Electrical Durability
- 10000 Cycles
- For Use With
- Electrical Distribution Equipment, Industrial Control Panels
- Frame Size
- 125A, BG
- Frame Type
- BGA
- Height
- 5.39"
- Ik Degree Of Protection
- IK07
- Instantaneous Trip
- Fixed
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 60A
- Local Signalling
- Presence Of Auxiliary Contacts Flag Green
- Max. Air Rating
- 100 kA At 240V AC
- Max. Operating Temp.
- 158°F
- Max. Wire Size
- 2 AWG
- Mechanical Durability
- 20000 Cycles
- Min. Operating Temp.
- -13°F
- Min. Wire Size
- 14 AWG
- Mounting Height
- 4.5"
- Mounting Mode
- I Line
- Network Frequency
- 50/60 Hz
- No. Of 9 Mm Pitches
- 9
- No. Of Poles
- 3
- Number Of Poles
- 3
- Number Of Slots
- 3
- Operating Altitude
- 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
- Phase
- Three
- Phase Connection
- ABC
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 0.8"
- Quality Labels
- ce.png
- Quantity Per Set
- Set of 1
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 800V
- Rated Operational Voltage
- 525V
- Rated Service Breaking Capacity
- 65 kA @ 220-240V AC @ 50/60 Hz, 18 kA @ 500-525V AC @ 50/60 Hz, 35 kA @ 380-415V AC @ 50/60 Hz, 35 kA @ 440V AC @ 50/60 Hz
- Returnability
- Yes
- Suitability For Isolation
- Yes, IEC 60947-2
- Terminal Connection
- Al Mechanical Lug Off End, I-Line On End
- Tightening Torque
- 31.9 lbf.in. to 38.9 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 44.3 lbf.in. to 54.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 2/0 AWG
- Trip Type
- Thermal Magnetic
- Trip Unit Technology
- Thermal-Magnetic
- Utilisation Category
- Category A
- Voltage Type
- AC
- Width
- 3.19"
- Standards
- CSA C22.2 NO 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, NEMA AB1, NMX J-266, UL 489
Техническое резюме
SQUARE D BGA34060Y circuit breaker ideal for use with electrical control panels and switchboards for protection against faulty currents, Thermal magnetic trip unit delivers both time delayed and instantaneous current limiting functions in reverse feed aplications, Integral DIN rail mounting facility and lug terminals reduce installation and wiring setup time, Adheres to UL, CE and CSA standards, SQUARE D BGA34060Y circuit breaker ideal for use with electrical control panels and switchboards for protection against faulty currents, Thermal magnetic trip unit delivers both time delayed and instantaneous current limiting functions in reverse feed aplications, Integral DIN rail mounting facility and lug terminals reduce installation and wiring setup time, Adheres to UL, CE and CSA standards
Square D
Марка основана в Детройте в 1902 году, с 1991 года принадлежит Schneider Electric. Номера бывают числовыми (462994), длинными числовыми (0320226101) и смешанными (10S40FSS); один знак меняет исполнение.