Square D CE6GUG BJL36060

Ключевые характеристики BJL36060

Серия
BJL36060
Item
Circuit Breaker
Ac Voltage Rating
690V AC

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
BJL36060
Item
Circuit Breaker
Ac Voltage Rating
690V AC
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
60A
Awg Gauge
6 AWG to 2/0 AWG, 14 AWG to 3/0 AWG
Breaking Capacity
100 kA 208Y/120V AC 50/60 Hz UL 489, 100 kA 240V AC 50/60 Hz UL 489, 65 kA 480/277V AC 50/60 Hz UL 489, 65 kA 480V AC 50/60 Hz UL 489, 25 kA 600Y/347V AC 50/60 Hz UL 489, 50 kA 250V DC UL 489
Breaking Capacity Code
J
Circuit Breaker Actuator
Toggle
Circuit Breaker Application
HACR Rated
Circuit Breaker Mounting Style
Unit Mount
Circuit Breaker Type
Standard
Color
Gray
Component Type
Circuit Breaker
Connection Pitch
1.06"
Continuous Amps Rating
80%
Control Type
Toggle
Dc Voltage Rating
Not Rated
Depth
3.15"
Device Application
Distribution
Electrical Connection
Everlink Lug, Line, Load
Electrical Durability
10000 Cycles
For Use With
Electrical Distribution Equipment, Industrial Control Panels
Frame Size
125A/BJ
Frame Type
BJL
Height
5.39"
Ik Degree Of Protection
IK07
Instantaneous Trip
Fixed
Ip Degree Of Protection
IP40
Line Rated Amps
60A
Local Signalling
Presence Of Auxiliary Contacts Flag Green
Max. Operating Temp.
158°F
Maximum Air Rating
100 Ka @ 120/240V Ac
Maximum Wire Size
2 AWG, 3 AWG
Mechanical Durability
20000 Cycles
Min. Operating Temp.
-13°F
Minimum Wire Size
14 AWG, 6 AWG
Mounting Mode
Clip On 35 mm x 15 mm Symmetrical Din Rail, By Screws Plate
Network Frequency
50/60 Hz
No. Of 9 Mm Pitches
9
No. Of Poles
3
Number Of Poles
3
Number Of Slots
3
Operating Altitude
0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase
Three
Phase Connection
ABC
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
0.8"
Quality Labels
ce.png
Quantity Per Set
Set of 1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
800V
Rated Operational Voltage
690V
Rated Service Breaking Capacity
100 kA @ 220-240V AC @ 50/60 Hz, 25 kA @ 500-525V AC @ 50/60 Hz, 10 kA @ 690V AC @ 50/60 Hz, 65 kA @ 380-415V AC @ 50/60 Hz, 65 kA @ 440V AC @ 50/60 Hz
Returnability
Yes
Suitability For Isolation
Yes, IEC 60947-2
Terminal Connection
Everlink Lug Both Ends
Tightening Torque
44.3 lbf.in. @ 0.004 sq. in. to 0.02 sq. in. @ 14 AWG to 4 AWG, 79.7 lbf.in. @ 0.04 sq. in. to 0.1 sq. in. @ 3 AWG to 3/0 AWG
Trip Type
Thermal Magnetic
Trip Unit Technology
Thermal-Magnetic
Utilisation Category
Category A
Voltage
600V
Voltage Type
AC
Width
3.19"
Standards
CSA C22.2 NO 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, NEMA AB1, NMX J-266, UL 489
Техническое резюме
Square D BJL36060 molded case circuit breaker designed for protection against faulty currents in panelboards and switchboards, Features a non-interchangeable, thermal magnetic trip for both long-time and instantaneous trip functions, 3 pole unit having built-in DIN rail mounting and patented EverLink lug connections on line & load ends to provide easy service and repairs, Features dual-break rotating contacts reducing the amount of peak current during a short circuit fault, Square D BJL36060 molded case circuit breaker designed for protection against faulty currents in panelboards and switchboards, Features a non-interchangeable, thermal magnetic trip for both long-time and instantaneous trip functions, 3 pole unit having built-in DIN rail mounting and patented EverLink lug connections on line & load ends to provide easy service and repairs, Features dual-break rotating contacts reducing the amount of peak current during a short circuit fault

Square D

Марка основана в Детройте в 1902 году, с 1991 года принадлежит Schneider Electric. Номера бывают числовыми (462994), длинными числовыми (0320226101) и смешанными (10S40FSS); один знак меняет исполнение.