Дата обновления:

Square D CE6HDN LA36400MT

Ключевые характеристики LA36400MT

Серия
LA36400MT
Item
Circuit Breaker
Amps
400A

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
LA36400MT
Item
Circuit Breaker
Amps
400A
Breaking Capacity Code
A
Circuit Breaker Application
HACR Rated
Component Type
Circuit Breaker
Depth
5.84"
Electrical Connection
Lugs, Load, I-Line Connection, Line
Frame Type
LA
Height
11"
Line Rated Amps
400A
Magnetic Hold Amps
2000A
Magnetic Tripping Amps
4000A
Mounting Mode
I Line
No. Of Poles
3
No. Of Wires
3
Number Of Poles
3
Phase Connection
ABC
Returnability
No
Tightening Torque
115.06 lbf.in. @ 0.07 sq. in. to 0.5 sq. in. @ 1 AWG to 600 kcmil, 115.06 lbf.in. @ 0.07 sq. in. to 0.2 sq. in. @ 1 AWG to 250 kcmil
Trip Unit Technology
Thermal-Magnetic
Voltage
600V
Voltage Type
AC
Width
6"
Warranty
18 Months
Техническое резюме
Square D LA36400MT I-Line molded case circuit breaker for protecting electrical circuits & equipment against current overloads & short-circuits in control panels & switchboards, 3 pole, 3 phase (ABC) configuration & compact LA frame design for limiting overcurrent, Features thermal magnetic trip for both long-time & instantaneous trip functions against mild nuisance tripping & severe short-circuits, respectively, Plug-in connection with load side lug terminals for establishing a secure connection and accommodating wires (aluminium / copper) of sizes between 1 AWG & 250 kcmil, IEC-approved, CSA-certified and UL-listed, Square D LA36400MT I-Line molded case circuit breaker for protecting electrical circuits & equipment against current overloads & short-circuits in control panels & switchboards, 3 pole, 3 phase (ABC) configuration & compact LA frame design for limiting overcurrent, Features thermal magnetic trip for both long-time & instantaneous trip functions against mild nuisance tripping & severe short-circuits, respectively, Plug-in connection with load side lug terminals for establishing a secure connection and accommodating wires (aluminium / copper) of sizes between 1 AWG & 250 kcmil, IEC-approved, CSA-certified and UL-listed

Square D

Выключатель подбирают по номинальному току, числу полюсов и напряжению, контактор — по току и напряжению катушки. В запросе нужен полный номер с шильдика; если он не читается, приложите фото.
Подробнее о бренде