Square D CE6HJP RGF36160U41A
Ключевые характеристики RGF36160U41A
- Серия
- RGF36160U41A
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- RGF36160U41A
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 1600A
- Awg Gauge
- 3/0 AWG to 750 kcmil
- Breaking Capacity
- AIR 65 kA 240V AC 50/60 Hz UL 489, AIR 35 kA 480V AC 50/60 Hz UL 489, AIR 18 kA 600V AC 50/60 Hz UL 489, Icu 50 kA 240V AC 50/60 Hz IEC 60947-2, Icu 35 kA 380/415V AC 50/60 Hz IEC 60947-2
- Breaking Capacity Code
- G
- Circuit Breaker Application
- HACR Rated
- Component Type
- Circuit Breaker
- Continuous Amps Rating
- 80%
- Control Type
- Operating Handle
- Depth
- 14.49"
- Device Application
- Distribution
- Electrical Connection
- Busbar Connection, Line, Load
- Frame Type
- RGF
- Height
- 16.24"
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 1600A
- Local Signalling
- Alarm 1 LED Yellow Long-Time Pick Up, 1 LED Red Long-Time Pick Up, Trip Causes 1 LED Red, 1 LED Red Digital Ammeter, Phase-Loading LED Green Load Balancing
- Mounting Mode
- Unit Mount Busbar
- Mounting Support
- Busbar
- Network Frequency
- 50/60 Hz
- No. Of Poles
- 3
- Number Of Poles
- 3
- Number Of Slots
- 4
- Operating Altitude
- 0 ft.. to 6561.68 ft. Without Derating, 13123.36 ft. With Derating
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 1.4"
- Quality Labels
- ce.png
- Quantity Per Set
- 1
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 750V
- Rated Operational Voltage
- 600V
- Rated Service Breaking Capacity
- 25 kA @ 240V AC @ 50/60 Hz, 20 kA @ 380/415V AC @ 50/60 Hz
- Returnability
- Yes
- Suitability For Isolation
- Yes, IEC 60947-2
- Tightening Torque
- 68 N-m
- Trip Unit Name
- Micro Logic 3.0 A
- Trip Unit Technology
- Electronic, Ammeter, MicroLogic 3 A, LI
- Utilisation Category
- Category A
- Voltage Type
- AC
- Width
- 16.54"
- Warranty
- 18 Months
Техническое резюме
Square D RGF36160U41A circuit breaker designed to provide protection against short-circuit and overload conditions, Unique MicroLogic 3.0 processor featuring true RMS sensing and thermal imaging for measuring and monitoring the dissipated power of applied voltage, Integrated with line- and load-side lug terminals suitable for use with busbars, Meets UL-listed, CSA-marked and IEC-rated requirements, Square D RGF36160U41A circuit breaker designed to provide protection against short-circuit and overload conditions, Unique MicroLogic 3.0 processor featuring true RMS sensing and thermal imaging for measuring and monitoring the dissipated power of applied voltage, Integrated with line- and load-side lug terminals suitable for use with busbars, Meets UL-listed, CSA-marked and IEC-rated requirements
Square D
Выключатель подбирают по номинальному току, числу полюсов и напряжению, контактор — по току и напряжению катушки. В запросе нужен полный номер с шильдика; если он не читается, приложите фото.