Дата обновления:

Square D CE6HJW PJA36100U41A

Ключевые характеристики PJA36100U41A

Серия
PJA36100U41A
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
PJA36100U41A
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
1000A
Awg Gauge
3/0 AWG to 500 kcmil
Breaking Capacity
AIR 100 kA 240V AC 50/60 Hz UL 489, AIR 65 kA 480V AC 50/60 Hz UL 489, AIR 25 kA 600V AC 50/60 Hz UL 489, Icu 65 kA 240V AC 50/60 Hz IEC 60947-2, Icu 50 kA 380/415V AC 50/60 Hz IEC 60947-2
Breaking Capacity Code
J
Circuit Breaker Application
HACR Rated
Component Type
Circuit Breaker
Continuous Amps Rating
80%
Control Type
Toggle
Depth
8.05"
Device Application
Distribution
Electrical Connection
I-Line Connection, Line, Lugs, Load
Frame Type
PJA
Height
16.16"
Ip Degree Of Protection
IP40
Line Rated Amps
1000A
Local Signalling
1 Trip Indicator Green
Long Time Pick-up Adjustment Range
0.4-1 Times Ir
Mounting Height
9"
Mounting Mode
I Line Bracket
Mounting Support
Bracket
Network Frequency
50/60 Hz
No. Of Poles
3
Number Of Poles
3
Number Of Slots
5
Operating Altitude
0 ft.. to 6561.68 ft. Without Derating, 13123.36 ft. With Derating
Phase Connection
ABC
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
1.2"
Quality Labels
ce.png
Quantity Per Set
1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
750V
Rated Operational Voltage
600V
Rated Service Breaking Capacity
35 kA @ 240V AC @ 50/60 Hz, 25 kA @ 380/415V AC @ 50/60 Hz
Returnability
Yes
Tightening Torque
442.5 lbf.in. @ 0.1 sq. in. to 0.4 sq. in. @ 4 x 3/0 AWG to 500 kcmil, 8.9 lbf.in. to 11.5 lbf.in.
Trip Unit Name
Micro Logic 3.0 A
Trip Unit Technology
Electronic, Ammeter, MicroLogic 3 A, LI
Voltage
600V
Voltage Type
AC
Width
8.27"
Warranty
18 Months
Техническое резюме
Square D PJA36100U41A PowerPact P circuit breaker for use with switchboards and panelboards to prevent overload or short-circuit occurrences, Thermal-magnetic trip unit offers instantaneous and long-time current limiting functions, Features I-Line style plug-in mounting for ease in installation; suitable for reverse feed applications, Provides interrupt ratings of 100kA at 240VAC, 65kA at 480VAC and 25kA at 600VAC, UL listed, Square D PJA36100U41A PowerPact P circuit breaker for use with switchboards and panelboards to prevent overload or short-circuit occurrences, Thermal-magnetic trip unit offers instantaneous and long-time current limiting functions, Features I-Line style plug-in mounting for ease in installation; suitable for reverse feed applications, Provides interrupt ratings of 100kA at 240VAC, 65kA at 480VAC and 25kA at 600VAC, UL listed

Square D

Выключатель подбирают по номинальному току, числу полюсов и напряжению, контактор — по току и напряжению катушки. В запросе нужен полный номер с шильдика; если он не читается, приложите фото.
Подробнее о бренде