Ключевые характеристики QOB340VH-1021
- Серия
- QOB340VH-1021
- Item
- Bolt On Circuit Breaker
- Ambient Rating
- 104°F
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- QOB340VH-1021
- Item
- Bolt On Circuit Breaker
- Ambient Rating
- 104°F
- Amps
- 40A
- Amps Rating
- 40A
- Circuit Breaker Type
- Standard
- Depth
- 2.9"
- Electrical Connection
- Box Lugs
- Frame Type
- QOB
- Height
- 3.1"
- Interrupt Rating
- 22 kA @ 120/240V AC, 22 kA @ 240V AC, 22 kA @ 120V AC
- Mounting Type
- Bolt On
- No. Of Panel Spaces
- 4
- No. Of Poles
- 3
- Number Of Poles
- 3
- Options
- Shunt Trip 120/208/240V AC
- Ratings
- HACR Rated
- Returnability
- Yes
- Tightening Torque
- 49.6 lbf.-in.
- Voltage
- 240V
- Voltage Rating
- 120/240V AC
- Voltage Type
- AC
- Width
- 3"
- Wire Size
- 8 AWG to 2 AWG
- Warranty
- 18 Months
Техническое резюме
Square D QOB340VH-1021 circuit breaker designed for providing overcurrent protection and switching AC and DC systems, Bolt-on mounting facility allows quick installation and repair services in NQO and NQOD panelboards, 3-pole design featuring tripping mechanism for allowing all the poles to open simultaneously, irrespective of the fault current flowing in any pole of the circuit, Thermal-magnetic trip delivers instantaneous and long-time current limiting functions and a Visi-Trip indicator for detecting open contacts during excessive current surges, Shunt trip terminals allow remote tripping and accept (2) copper leads of the size range 14 - 12 AWG, UL-listed and CSA-certified, Square D QOB340VH-1021 circuit breaker designed for providing overcurrent protection and switching AC and DC systems, Bolt-on mounting facility allows quick installation and repair services in NQO and NQOD panelboards, 3-pole design featuring tripping mechanism for allowing all the poles to open simultaneously, irrespective of the fault current flowing in any pole of the circuit, Thermal-magnetic trip delivers instantaneous and long-time current limiting functions and a Visi-Trip indicator for detecting open contacts during excessive current surges, Shunt trip terminals allow remote tripping and accept (2) copper leads of the size range 14 - 12 AWG, UL-listed and CSA-certified