Square D CE6HVV BDA260804

Ключевые характеристики BDA260804

Серия
BDA260804
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
BDA260804
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
80A
Awg Gauge
14 AWG to 2/0 AWG
Breaking Capacity
25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489
Breaking Capacity Code
D
Circuit Breaker Application
HACR Rated
Color
Gray
Component Type
Circuit Breaker
Connection Pitch
1.06"
Continuous Amps Rating
80%
Control Type
Toggle
Depth
3 1/2"
Device Application
Distribution
Electrical Connection
I-Line Connection, Line, Lugs, Load
Electrical Durability
10000 Cycles
Frame Type
BDA
Height
5 2/5"
Ik Degree Of Protection
IK07
Ip Degree Of Protection
IP40
Line Rated Amps
80A
Local Signalling
Presence Of Auxiliary Contacts Flag Green
Mechanical Durability
20000 Cycles
Mounting Height
3"
Mounting Mode
I Line
Network Frequency
50/60 Hz
No. Of 9 Mm Pitches
6
No. Of Poles
2
Number Of Poles
2
Number Of Slots
2
Operating Altitude
0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase Connection
BC
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
0.8"
Quality Labels
ce.png
Quantity Per Set
Set of 1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
800V
Rated Operational Voltage
525V
Rated Service Breaking Capacity
25 kA @ 220-240V AC @ 50/60 Hz, 14 kA @ 500-525V AC @ 50/60 Hz, 18 kA @ 380-415V AC @ 50/60 Hz, 18 kA @ 440V AC @ 50/60 Hz
Returnability
No
Suitability For Isolation
Yes, IEC 60947-2
Tightening Torque
31.9 lbf.in. to 38.9 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 44.3 lbf.in. to 54.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 2/0 AWG
Trip Unit Technology
Thermal-Magnetic
Utilisation Category
Category A
Voltage
600V
Voltage Type
AC
Width
2.1"
Техническое резюме
Square D BDA260804 circuit breaker designed for protection of sensitive electronic components from current overloads and short circuits, Thermal magnetic trip instantly reacts against severe power surges while avoiding tripping on mild overloads, Unique I-Line style plug-in comfortably mounts into all kinds of panelboards & switchboards for fast installation and repair, Comes equipped with load side lugs that can accommodate aluminium / copper wire of sizes from 14 to 2/0 AWG, UL listed and CSA certified, Square D BDA260804 circuit breaker designed for protection of sensitive electronic components from current overloads and short circuits, Thermal magnetic trip instantly reacts against severe power surges while avoiding tripping on mild overloads, Unique I-Line style plug-in comfortably mounts into all kinds of panelboards & switchboards for fast installation and repair, Comes equipped with load side lugs that can accommodate aluminium / copper wire of sizes from 14 to 2/0 AWG, UL listed and CSA certified

Square D