Square D CE6HYA BJA260154
Ключевые характеристики BJA260154
- Серия
- BJA260154
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- BJA260154
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 15A
- Awg Gauge
- 14 AWG to 2/0 AWG
- Breaking Capacity
- 100 kA 208Y/120V AC 50/60 Hz UL 489, 100 kA 240V AC 50/60 Hz UL 489, 65 kA 480/277V AC 50/60 Hz UL 489, 65 kA 480V AC 50/60 Hz UL 489, 25 kA 600Y/347V AC 50/60 Hz UL 489, 50 kA 250V DC UL 489
- Breaking Capacity Code
- J
- Circuit Breaker Application
- HACR Rated
- Color
- Gray
- Component Type
- Circuit Breaker
- Connection Pitch
- 1.06"
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Depth
- 3 1/2"
- Device Application
- Distribution
- Electrical Connection
- I-Line Connection, Line, Lugs, Load
- Electrical Durability
- 10000 Cycles
- Frame Type
- BJA
- Height
- 5 2/5"
- Ik Degree Of Protection
- IK07
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 15A
- Local Signalling
- Presence Of Auxiliary Contacts Flag Green
- Mechanical Durability
- 20000 Cycles
- Mounting Height
- 3"
- Mounting Mode
- I Line
- Network Frequency
- 50/60 Hz
- No. Of 9 Mm Pitches
- 6
- No. Of Poles
- 2
- Number Of Poles
- 2
- Number Of Slots
- 2
- Operating Altitude
- 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
- Phase Connection
- BC
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 0.8"
- Quality Labels
- ce.png
- Quantity Per Set
- Set of 1
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 800V
- Rated Operational Voltage
- 690V
- Rated Service Breaking Capacity
- 100 kA @ 220-240V AC @ 50/60 Hz, 25 kA @ 500-525V AC @ 50/60 Hz, 10 kA @ 690V AC @ 50/60 Hz, 65 kA @ 380-415V AC @ 50/60 Hz, 65 kA @ 440V AC @ 50/60 Hz
- Returnability
- Yes
- Suitability For Isolation
- Yes, IEC 60947-2
- Tightening Torque
- 31.9 lbf.in. to 38.9 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 44.3 lbf.in. to 54.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 2/0 AWG
- Trip Unit Technology
- Thermal-Magnetic
- Utilisation Category
- Category A
- Voltage
- 600V
- Voltage Type
- AC
- Width
- 2.1"
Техническое резюме
Square D BJA260154 circuit breaker ideal for reverse feed applications to protect circuits against current overloads and short circuits, Accommodates 14 - 2 AWG aluminium / copper wires, Features a non-interchangeable thermal-magnetic trip for providing both long-time and instantaneous current limiting functions, I-Line style plug-in design with load-side lug terminals for easy wiring & eliminating loose connections, Meets UL 489, NEMA AB1, CSA C22.2 No 5 & IEC 60947-5-1 standards, Square D BJA260154 circuit breaker ideal for reverse feed applications to protect circuits against current overloads and short circuits, Accommodates 14 - 2 AWG aluminium / copper wires, Features a non-interchangeable thermal-magnetic trip for providing both long-time and instantaneous current limiting functions, I-Line style plug-in design with load-side lug terminals for easy wiring & eliminating loose connections, Meets UL 489, NEMA AB1, CSA C22.2 No 5 & IEC 60947-5-1 standards
Square D
Аппараты Square D работают в шкафах управления станков, насосных станций и вентиляции. Выключатели защищают линию, контактор коммутирует нагрузку, термоблок следит за перегрузкой двигателя.