Square D CE6JKW HDA260204
Ключевые характеристики HDA260204
- Серия
- HDA260204
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- HDA260204
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 20A
- Awg Gauge
- 14 AWG to 3/0 AWG
- Breaking Capacity
- 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz, 14 kA 600V AC 50/60 Hz, 20 kA 250V DC
- Breaking Capacity Code
- D
- Circuit Breaker Application
- HACR Rated
- Color
- Black
- Communication Interface
- Modbus, Ethernet
- Component Type
- Circuit Breaker
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Depth
- 3.4"
- Device Application
- Distribution
- Electrical Connection
- I-Line Connection, Line, Lugs, Load
- Frame Type
- HDA
- Height
- 6 2/5"
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 20A
- Local Signalling
- Switched Off 1 Trip Indicator Green
- Magnetic Hold Amps
- 350A
- Magnetic Tripping Amps
- 750A
- Mounting Height
- 3"
- Mounting Mode
- I Line Bracket
- Mounting Support
- Bracket
- Network Frequency
- 50/60 Hz
- No. Of Poles
- 2
- Number Of Poles
- 2
- Number Of Slots
- 5
- Operating Altitude
- 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
- Phase Connection
- BC
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 0.6"
- Quality Labels
- ce.png
- Quantity Per Set
- 1
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 750V
- Rated Operational Voltage
- 690V
- Rated Service Breaking Capacity
- 25 kA @ 220/240V AC @ 50/60 Hz, 18 kA @ 380/440/415V AC @ 50/60 Hz, 14 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
- Returnability
- Yes
- Suitability For Isolation
- Yes, IEC 60947-2
- Tightening Torque
- 44.3 lbf.in. @ 0.004 sq. in. to 0.009 sq. in. @ 14 AWG to 10 AWG, 123.9 lbf.in. @ 0.02 sq. in. to 0.1 sq. in. @ 8 AWG to 3/0 AWG
- Trip Unit Technology
- Thermal-Magnetic
- Utilisation Category
- Category A
- Voltage
- 600V
- Voltage Type
- AC
- Width
- 4.09"
- Warranty
- 18 Months
Техническое резюме
Square D HDA260204 I-Line circuit breaker designed for protection against short circuit and overload conditions, Unique I-Line style plug-in mounting allows easy installation and removal of circuit breakers used in I-Line panelboards, Capable of withstanding temperatures up to 40 degrees C and prevents nuisance tripping on mild overloads while quickly responding to large overcurrent conditions without intentional time delay, Fixed thermal magnetic trip provides both long time and instantaneous functions for maximum current limiting protection, UL-listed and CSA-certified, Square D HDA260204 I-Line circuit breaker designed for protection against short circuit and overload conditions, Unique I-Line style plug-in mounting allows easy installation and removal of circuit breakers used in I-Line panelboards, Capable of withstanding temperatures up to 40 degrees C and prevents nuisance tripping on mild overloads while quickly responding to large overcurrent conditions without intentional time delay, Fixed thermal magnetic trip provides both long time and instantaneous functions for maximum current limiting protection, UL-listed and CSA-certified