Дата обновления:

Square D CE6JPP JDA36200SA

Ключевые характеристики JDA36200SA

Серия
JDA36200SA
Item
Circuit Breaker
Accessory/separate Part Type
Shunt Trip 110-130V AC Compartment

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
JDA36200SA
Item
Circuit Breaker
Accessory/separate Part Type
Shunt Trip 110-130V AC Compartment
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
200A
Awg Gauge
3/0 AWG to 350 kcmil
Breaking Capacity
25 kA 240V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz, 14 kA 600V AC 50/60 Hz, 20 kA 250V DC
Breaking Capacity Code
D
Circuit Breaker Application
HACR Rated
Communication Interface
Modbus, Ethernet
Component Type
Circuit Breaker
Continuous Amps Rating
80%
Control Type
Toggle
Depth
3.4"
Device Application
Distribution
Electrical Connection
I-Line Connection, Line, Lugs, Load
Frame Type
JDA
Height
7 1/2"
Ip Degree Of Protection
IP40
Line Rated Amps
200A
Local Signalling
Switched Off 1 Trip Indicator Green
Long Time Pick-up Adjustment Range
0.25-1 Times In
Magnetic Hold Amps
1000A
Magnetic Tripping Amps
2000A
Mounting Height
4.5"
Mounting Mode
I Line Bracket
Mounting Support
Bracket
Network Frequency
50/60 Hz
No. Of Poles
3
Number Of Poles
3
Number Of Slots
5
Operating Altitude
0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
1"
Protection Type
Overload Protection, Short Circuit Protection
Quality Labels
ce.png
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
750V
Rated Operational Voltage
600V
Rated Service Breaking Capacity
25 kA @ 220/240V AC @ 50/60 Hz, 18 kA @ 380/440/415V AC @ 50/60 Hz, 14 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
Returnability
No
Suitability For Isolation
Yes, IEC 60947-2
Tightening Torque
221.3 lbf.in. @ 0.1 sq. in. to 0.3 sq. in. @ 3/0 AWG to 350 kcmil
Trip Unit Technology
Thermal-Magnetic
Utilisation Category
Category A
Voltage
600V
Voltage Type
AC
Width
4.09"
Warranty
18 Months
Техническое резюме
Square D JDA36200SA circuit breaker limits let-through currents, offering maximum protection to downstream components, Thermal magnetic trip unit allows both instantaneous and time-delayed functions for maximum overcurrent protection, Unique I-Line design with lug load terminals provides easy installation and hassle-free wiring configuration, Includes 120VAC shunt trip for remote opening of contacts for protection of solenoid (armature), UL-listed, CSA-cerified and CE-marked, Square D JDA36200SA circuit breaker limits let-through currents, offering maximum protection to downstream components, Thermal magnetic trip unit allows both instantaneous and time-delayed functions for maximum overcurrent protection, Unique I-Line design with lug load terminals provides easy installation and hassle-free wiring configuration, Includes 120VAC shunt trip for remote opening of contacts for protection of solenoid (armature), UL-listed, CSA-cerified and CE-marked

Square D

Марка основана в Детройте в 1902 году, с 1991 года принадлежит Schneider Electric. Номера бывают числовыми (462994), длинными числовыми (0320226101) и смешанными (10S40FSS); один знак меняет исполнение.