Square D CE6JQU JLA36175
Ключевые характеристики JLA36175
- Серия
- JLA36175
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- JLA36175
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 175A
- Awg Gauge
- 4 AWG to 4/0 AWG
- Breaking Capacity
- 125 kA 240V AC 50/60 Hz UL 489, 100 kA 480V AC 50/60 Hz UL 489, 50 kA 600V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 50 kA 500V DC UL 489
- Breaking Capacity Code
- L
- Circuit Breaker Application
- HACR Rated
- Communication Interface
- Modbus
- Component Type
- Circuit Breaker
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Depth
- 3.4"
- Electrical Connection
- I-Line Connection, Line, Lugs, Load
- Frame Type
- JLA
- Height
- 7 1/2"
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 175A
- Local Signalling
- Switched Off 1 Trip Indicator Green
- Long Time Pick-up Adjustment Range
- 0.25-1 Times In
- Magnetic Hold Amps
- 875A
- Magnetic Tripping Amps
- 1750A
- Mounting Height
- 4.5"
- Mounting Mode
- I Line Bracket
- Mounting Support
- Bracket
- Network Frequency
- 50/60 Hz
- No. Of Poles
- 3
- Number Of Poles
- 3
- Number Of Slots
- 5
- Operating Altitude
- 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
- Phase Connection
- ABC
- Pollution Degree
- 3°
- Power Wire Stripping Length
- 1"
- Protection Type
- Overload Protection, Short Circuit Protection
- Quality Labels
- ce.png
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 750V
- Rated Operational Voltage
- 600V
- Rated Service Breaking Capacity
- 125 kA @ 220/240V AC @ 50/60 Hz, 100 kA @ 380/440/415V AC @ 50/60 Hz, 50 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
- Returnability
- No
- Suitability For Isolation
- Yes, IEC 60947-2
- Tightening Torque
- 25 N-m
- Trip Unit Technology
- Thermal-Magnetic
- Utilisation Category
- Category A
- Voltage
- 600V
- Voltage Type
- AC
- Width
- 4.09"
- Warranty
- 18 Months
Техническое резюме
Square D JLA36175 circuit breaker designed for limiting let-through currents for protecting downstream components in power distribution applications, Supports 4 AWG copper & aluminium wiring, I-Line connection line & load side lug terminals for eliminating loose connections while ensuring ease-of-wiring, Non-interchangeable thermal magnetic trip for providing both long time & instantaneous trip functions for reacting against severe short-circuits at once while avoiding tripping on mild overloads, UL-listed, IEC-approved & CSA-certified, Square D JLA36175 circuit breaker designed for limiting let-through currents for protecting downstream components in power distribution applications, Supports 4 AWG copper & aluminium wiring, I-Line connection line & load side lug terminals for eliminating loose connections while ensuring ease-of-wiring, Non-interchangeable thermal magnetic trip for providing both long time & instantaneous trip functions for reacting against severe short-circuits at once while avoiding tripping on mild overloads, UL-listed, IEC-approved & CSA-certified
Square D
Марка основана в Детройте в 1902 году, с 1991 года принадлежит Schneider Electric. Номера бывают числовыми (462994), длинными числовыми (0320226101) и смешанными (10S40FSS); один знак меняет исполнение.
Подробнее о бренде