Square D CE6JTH BGL36090
Ключевые характеристики
- Серия
- BGL36090
- Item
- Circuit Breaker
- Ac Voltage Rating
- 525V AC
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 90A
- Awg Gauge
- 6 AWG to 2/0 AWG, 14 AWG to 3/0 AWG
- Breaking Capacity
- 65 kA 208Y/120V AC 50/60 Hz UL 489, 65 kA 240V AC 50/60 Hz UL 489, 35 kA 480/277V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 18 kA 600Y/347V AC 50/60 Hz UL 489
- Breaking Capacity Code
- G
- Circuit Breaker Actuator
- Toggle
- Circuit Breaker Application
- HACR Rated
- Circuit Breaker Mounting Style
- Unit Mount
- Circuit Breaker Type
- Standard
- Color
- Gray
- Component Type
- Circuit Breaker
- Connection Pitch
- 1.06"
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Dc Voltage Rating
- Not Rated
- Depth
- 3.15"
- Device Application
- Distribution
- Electrical Connection
- Everlink Lug, Line, Load
- Electrical Durability
- 10000 Cycles
- For Use With
- Electrical Distribution Equipment, Industrial Control Panels
- Frame Size
- 125A, BG
- Frame Type
- BGL
- Height
- 5.39"
- Ik Degree Of Protection
- IK07
- Instantaneous Trip
- Fixed
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 90A
- Local Signalling
- Presence Of Auxiliary Contacts Flag Green
- Max. Air Rating
- 100 kA At 240V AC
- Max. Operating Temp.
- 158°F
- Maximum Wire Size
- 2 AWG, 3 AWG
- Mechanical Durability
- 20000 Cycles
- Min. Operating Temp.
- -13°F
- Minimum Wire Size
- 14 AWG, 6 AWG
- Mounting Mode
- Clip On 35 mm x 15 mm Symmetrical Din Rail, By Screws Plate
- Network Frequency
- 50/60 Hz
- No. Of 9 Mm Pitches
- 9
- No. Of Poles
- 3
- Number Of Poles
- 3
- Number Of Slots
- 3
- Operating Altitude
- 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
- Phase
- Three
- Phase Connection
- ABC
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 0.8"
- Quality Labels
- ce.png
- Quantity Per Set
- Set of 1
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 800V
- Rated Operational Voltage
- 525V
- Rated Service Breaking Capacity
- 65 kA @ 220-240V AC @ 50/60 Hz, 18 kA @ 500-525V AC @ 50/60 Hz, 35 kA @ 380-415V AC @ 50/60 Hz, 35 kA @ 440V AC @ 50/60 Hz
- Returnability
- Yes
- Suitability For Isolation
- Yes, IEC 60947-2
- Terminal Connection
- Everlink Lug Both Ends
- Tightening Torque
- 44.3 lbf.in. @ 0.004 sq. in. to 0.02 sq. in. @ 14 AWG to 4 AWG, 79.7 lbf.in. @ 0.04 sq. in. to 0.1 sq. in. @ 3 AWG to 3/0 AWG
- Trip Type
- Thermal Magnetic
- Trip Unit Technology
- Thermal-Magnetic
- Utilisation Category
- Category A
- Voltage
- 600V
- Voltage Type
- AC
- Width
- 3.19"
- Standards
- CSA C22.2 NO 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, NEMA AB1, NMX J-266, UL 489
Техническое резюме
Square D BGL36090 circuit breaker designed for use in power distribution systems to open a circuit under short circuit or overload conditions, Non-interchangeable trip mechanism with long-time and instantaneous trip functions, Feed-thru design with EverLink connectors ensure faster installation & repair, Line and load side lug terminals accommodate copper and aluminium wire sizes ranging from 14 to 3/0 AWG (rigid or stranded), UL listed and CSA certified, Square D BGL36090 circuit breaker designed for use in power distribution systems to open a circuit under short circuit or overload conditions, Non-interchangeable trip mechanism with long-time and instantaneous trip functions, Feed-thru design with EverLink connectors ensure faster installation & repair, Line and load side lug terminals accommodate copper and aluminium wire sizes ranging from 14 to 3/0 AWG (rigid or stranded), UL listed and CSA certified
Square D
Марка основана в Детройте в 1902 году, с 1991 года принадлежит Schneider Electric. Номера бывают числовыми (462994), длинными числовыми (0320226101) и смешанными (10S40FSS); один знак меняет исполнение.
Подробнее о бренде