Square D CE6JVB LLA36400U31X
Ключевые характеристики LLA36400U31X
- Серия
- LLA36400U31X
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
Преимущества работы с Raxwell
- Доставляем во все регионы России
- Берём всё под ключ — от подбора до доставки
- Быстро считаем стоимость и соблюдаем сроки
- Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
- Серия
- LLA36400U31X
- Item
- Circuit Breaker
- Ambient Air Temp. For Operation
- -13°F to +158°F
- Ambient Air Temp. For Storage
- -58°F to +185°F
- Amps
- 400A
- Awg Gauge
- 3/0 AWG to 500 kcmil
- Breaking Capacity
- 125 kA 240V AC 50/60 Hz UL 489, 100 kA 480V AC 50/60 Hz UL 489, 50 kA 600V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 50 kA 500V DC UL 489
- Breaking Capacity Code
- L
- Circuit Breaker Application
- HACR Rated
- Color
- Black
- Communication Interface
- Modbus, Ethernet
- Component Type
- Circuit Breaker
- Continuous Amps Rating
- 80%
- Control Type
- Toggle
- Depth
- 4.3"
- Device Application
- Distribution
- Electrical Connection
- I-Line Connection, Line, Lugs, Load
- Frame Type
- LLA
- Height
- 13 2/5"
- Ip Degree Of Protection
- IP40
- Line Rated Amps
- 400A
- Local Signalling
- Ready 1 LED Green, Alarm 1 LED 90% IR Orange, Alarm LED 105% IR Red, Switched Off 1 Trip Indicator Green
- Long Time Pick-up Adjustment Range
- 0.25-1 Times In
- Mounting Height
- 6"
- Mounting Mode
- I Line Bracket
- Mounting Support
- Bracket
- Network Frequency
- 50/60 Hz
- No. Of Poles
- 3
- Number Of Poles
- 3
- Number Of Slots
- 5
- Operating Altitude
- 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
- Phase Connection
- ABC
- Pollution Degree
- 3 IEC 60947-1
- Power Wire Stripping Length
- 1.2"
- Protection Technology
- Current Limiter
- Rated Impulse Withstand Voltage
- 8 kV
- Rated Insulation Voltage
- 750V
- Rated Operational Voltage
- 600V
- Rated Service Breaking Capacity
- 125 kA @ 220/240V AC @ 50/60 Hz, 100 kA @ 380/440/415V AC @ 50/60 Hz, 50 kA @ 500/525V AC @ 50/60 Hz, 20 kA @ 250V DC, 20 kA @ 500V DC
- Returnability
- Yes
- Suitability For Isolation
- Yes, IEC 60947-2
- Tightening Torque
- 442.5 lbf.in. @ 0.1 sq. in. to 0.4 sq. in. @ 3/0 AWG to 500 kcmil
- Trip Unit Name
- Micro Logic 3.3
- Trip Unit Technology
- Electronic, Standard, MicroLogic 3.3, LI
- Utilisation Category
- Category A
- Voltage
- 600V
- Voltage Type
- AC
- Width
- 5.5"
- Warranty
- 18 Months
Техническое резюме
Square D LLA36400U31X circuit breaker designed to provide protection against short circuits and overloads in distribution systems, MicroLogic 3.3 processor featuring true RMS sensing and thermal imaging for measuring and monitoring the dissipated power of applied voltage, Features I-Line plug-in mounting & load side lug terminals for eliminating loose connections while accommodating 500 kcmil - 3 AWG aluminium & copper wiring, Meets UL-listed, CE-rated and CSA-marked requirements, Square D LLA36400U31X circuit breaker designed to provide protection against short circuits and overloads in distribution systems, MicroLogic 3.3 processor featuring true RMS sensing and thermal imaging for measuring and monitoring the dissipated power of applied voltage, Features I-Line plug-in mounting & load side lug terminals for eliminating loose connections while accommodating 500 kcmil - 3 AWG aluminium & copper wiring, Meets UL-listed, CE-rated and CSA-marked requirements
Square D
Марка основана в Детройте в 1902 году, с 1991 года принадлежит Schneider Electric. Номера бывают числовыми (462994), длинными числовыми (0320226101) и смешанными (10S40FSS); один знак меняет исполнение.
Подробнее о бренде