Дата обновления:

Square D CE6JVE PGL36080U33A

Ключевые характеристики PGL36080U33A

Серия
PGL36080U33A
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F

Преимущества работы с Raxwell

  • Доставляем во все регионы России
  • Берём всё под ключ — от подбора до доставки
  • Быстро считаем стоимость и соблюдаем сроки
  • Всегда на связи и сопровождаем на каждом этапе
Ключевые характеристики
Серия
PGL36080U33A
Item
Circuit Breaker
Ambient Air Temp. For Operation
-13°F to +158°F
Ambient Air Temp. For Storage
-58°F to +185°F
Amps
800A
Awg Gauge
3/0 AWG to 500 kcmil
Breaking Capacity
AIR 65 kA 240V AC 50/60 Hz UL 489, AIR 35 kA 480V AC 50/60 Hz UL 489, AIR 18 kA 600V AC 50/60 Hz UL 489, Icu 50 kA 240V AC 50/60 Hz IEC 60947-2, Icu 35 kA 380/415V AC 50/60 Hz IEC 60947-2
Breaking Capacity Code
G
Circuit Breaker Application
HACR Rated
Component Type
Circuit Breaker
Continuous Amps Rating
80%
Control Type
Toggle
Depth
8.05"
Device Application
Distribution
Electrical Connection
Lugs, Load, Line
Frame Type
PGL
Height
12.86"
Ip Degree Of Protection
IP40
Line Rated Amps
800A
Local Signalling
Overload 1 1 LED Amber, 1 Trip Indicator Green
Long Time Pick-up Adjustment Range
0.4-1 Times Ir
Network Frequency
50/60 Hz
No. Of Poles
3
Number Of Poles
3
Number Of Slots
5
Operating Altitude
0 ft.. to 6561.68 ft. Without Derating, 13123.36 ft. With Derating
Pollution Degree
3 IEC 60947-1
Power Wire Stripping Length
1"
Quality Labels
ce.png
Quantity Per Set
1
Rated Impulse Withstand Voltage
8 kV
Rated Insulation Voltage
750V
Rated Operational Voltage
600V
Rated Service Breaking Capacity
25 kA @ 240V AC @ 50/60 Hz, 20 kA @ 380/415V AC @ 50/60 Hz
Returnability
Yes
Tightening Torque
442.5 lbf.in. @ 0.1 sq. in. to 0.4 sq. in. @ 3 x 3/0 AWG to 500 Kcmil, 8.9 lbf.in. to 11.5 lbf.in.
Trip Unit Name
Micro Logic 5.0
Trip Unit Technology
Electronic, Standard, MicroLogic 5, LSI
Voltage
600V
Voltage Type
AC
Width
8.27"
Warranty
18 Months
Техническое резюме
Square D PGL36080U33A circuit breaker designed for protection against short circuit and overload conditions, Standard electronic trip unit with MicroLogic 5.0 processor allowing long-time, short-time and instantaneous current limiting functions, Line & load side lug terminals for secure connection in limited loadcentre space, Delivers interrupting ratings of 65kA @ 240VAC, 35kA @ 480VAC and 18kA @ 600VAC, UL-listed, IEC-approved and CSA-certified, Square D PGL36080U33A circuit breaker designed for protection against short circuit and overload conditions, Standard electronic trip unit with MicroLogic 5.0 processor allowing long-time, short-time and instantaneous current limiting functions, Line & load side lug terminals for secure connection in limited loadcentre space, Delivers interrupting ratings of 65kA @ 240VAC, 35kA @ 480VAC and 18kA @ 600VAC, UL-listed, IEC-approved and CSA-certified

Square D

Выключатель подбирают по номинальному току, числу полюсов и напряжению, контактор — по току и напряжению катушки. В запросе нужен полный номер с шильдика; если он не читается, приложите фото.